Dixie Double Can Seamers hermetically seam lightweight metal tops onto round, rigid containers of various sizes, types, and styles.
DESCRIPTION:
Model UVG+MD-AL-HMI WITH SIX OPERATING MODES:
The Model UVG+MD-AL-HMI include all the functions of our MultiFlush Model UVGMD, but we have also designed two new Operating Functions that allow the user to pull a Vacuum and then add a Positive Inert Gas Flush up to 26 PSI. Atmospheric/Vacuum Only/Vac with Inert Gas Flush/Multiflush/Positive Pressure Inert Gas Flush and Positive Pressure Inert Gas MultiFlush with Timed Delays. CE/UL Rated .75 HP Gearhead Motor Drive and Electronically Controlled Clutch-Brake/Air Lift/Vacuum System, 110/115 Vac, 50/60 Hz, 20 Amps. Vacuum Up To 28″Hg, Inert Gas Flush To 26” PSI. Program Values, Cycles, Timed Delays, Change Operating Modes, and Quick Reference Operating Instructions are Displayed on 7″ HMI Touch Screen.
CAN SIZE RANGE:
Less than 2” up to 6 1⁄4” in Diameter up to 15” Tall.
FLOOR SPACE:
28” x 34” x 82”H
SHIPPING WT:
800 LBS.
OPTIONS:
Customized to close cans smaller than 2”, to Accommodate Thermocouples, or with
Dome Type Lids. – Request Quotation
Transformer/vacuum pump for 220/50 or 60hz/1 Ph- Request Quotation
ADVANTAGES:
1. Positive Inert Gas Flush up to 26 PSI.
2. Positive Inert Gas MultiFlush Up to 3 Cycles
3. Vacuum/Gas MultiFlush 28” Hg to 1” Hg Up to 11 Cycles
4. Programmable Dwell (timed Delays) From 0.1 to 9.9 Seconds
5. Hermetically Seams Can After Programmable Functions Complete Cycle
6. Counts Cans Closed in Each of the 6 Operating Cycles
7. Maintenance Reminders at 5,000 Can Intervals
8. With Change Parts (Tooling) This Can Seamer Has Ability to Close Virtually Any
Size Can
9. Quick Reference Operator Manual Access on HMI Screen
MULTIVERSA COMMAND CENTER 7” HMI TOUCH SCREEN:
Select function, Set Values, Cycles and/or Time Delays On-Screen with the Touch of
a Finger. The Operational Functions are Monitored On-Screen During Each Seaming
Cycle.
EXPORT BOXING
(15″ Chamber) SHIPPING: 850 pounds – Request Quotation
TO OPERATE:
To Operate the Model UVG+MD-AL-HMI: Use Touch Screen to Select Operating Mode, Set Values for Vacuum, Gas Flush and Timed Delays. Position Filled Can and Lid. The Set Values, Cycles and Delays are Performed Precisely and Repetitiously Each Time the Vacuum Chamber Door is Closed, you press the Start Button on HMI and Before the Can and Lid are Joined and Hermetically Seamed. Requires 90 PSI/5 CFM Compressed Air to Operate.
The Positive Pressure Operating Function has two Operating Functions that the other 4 vacuum/Gas Flush to 1” Hg do not have:
1. Light Curtain Device and Pneumatic Door Clam Assemblies to Hold Chamber Door
Closed While Positive Inert Gas Flush is Applied
2. Before A Positive Inert Gas Flush, the Chamber is Vacuumed with a minimum of -3 PSI
(-6.108” Hg). All Vacuum Values(“Hg) are Converted to
-PSI (See Chart Below)
When working in the Positive Pressure Mode or the Positive Pressure MultiFlush Mode, the Positive Pressure Set Point Values are represented in PSI (Pounds per Square Inch). In this Operating Mode ONLY – Vacuum Set Point Values are represented in Negative (-) Pounds per Square Inch (-PSI). Since all other Operating Modes represent Vacuum Set Point
Values as Inches of Mercury (Hg”) the Chart below allows for Quick conversion reference
for programming and reporting purposes.
-1 PSI = -2.0360204571891” Hg (The values below are rounded to the nearest thousandth)
(0.001)
*-14 PSI = -28.504” Hg is Max Programmable Vacuum Set Point Value in the Positive
Pressure Operating Mode.